ORIGINAL RESEARCH | https://doi.org/10.5005/jp-journals-10015-1886 |
Comparison of Bond Strength of Luted Fiberglass Posts with Different Cementation Protocols: A Comparative In Vitro Study
1,2Postgraduate Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru
3Faculdade do Centro Oeste Paulista, Department of Dentistry, Sao Paulo, Brazil
4,5Academic Department of Rehabilitative Stomatology, Faculty of Dentistry, Universidad Nacional Mayor de San Marcos, Lima, Peru
6Postgraduate Department, CHANGE Research Working Group, Faculty of Health Sciences, Universidad Científica del Sur, Lima, Peru
Corresponding Author: Frank Mayta-Tovalino, Postgraduate Department, CHANGE Research Working Group, Faculty Health of Sciences, Universidad Cientifica del Sur, Lima, Peru, Phone: +51 1 6106400, e-mail: fmaytat@cientifica.edu.pe
ABSTRACT
Aim: To compare the bond strength of fiberglass posts luted with different adhesive luting protocols.
Materials and methods: Thirty bovine teeth that underwent endodontic treatment were used. The crowns were removed, and the root canals were prepared. In the first group, the posts were cemented with an etch-and-rinse protocol with universal adhesive and resin cement; for the second group, a self-etching protocol with universal adhesive and resin cement was adopted; for the third group, a protocol with self-adhesive cement was adopted. The roots of the teeth were sectioned into 2-mm thick specimens, corresponding to the middle, cervical, and apical thirds of the space prepared for the post. The specimens were pushed out using a universal testing machine. The normality of the data was tested by the Shapiro–Wilk test, and statistical analyses included ANOVA and Bonferroni test.
Results: The mean adhesion force was 21.2 ± 4.7 MPa in the first group, 22.6 ± 5.1 MPa in the second, and 12.3 ± 2.1 MPa in the third group. At the cervical level, the mean adhesion force was 17.5 ± 5.2 MPa, at the level of the middle third, it was 17.7 MPa ± 5.4, and at the apical level, 21.0 ± 7.3 MPa.
Conclusions: There were no significant differences in the mean adhesion’s forces between groups 1 and 2, while the values of group 3 were significantly lower than those of the other groups.
Clinical significance: This research allows us to know the impact of bonding systems on the different cementation protocols for fiberglass posts.
How to cite this article: Alvitez-Temoche D, Mendoza R, Calderón I, et al. Comparison of Bond Strength of Luted Fiberglass Posts with Different Cementation Protocols: A Comparative In Vitro Study. World J Dent 2022;13(1):40–45.
Source of support: Nil
Conflict of interest: None
Keywords: Bond strength, Cementation, Fiber post, In vitro study.
INTRODUCTION
The restoration of endodontically treated teeth can be a challenge because, in general, the teeth that undergo this treatment lose a large amount of coronary tissue, making it necessary to use posts as intraradicular retention elements for restoring the coronary nucleus.1,2 There are several types of posts; however, fiber posts are preferred by many clinicians because of their properties, such as elastic modulus close to that of dentin, esthetic appearance, and compatibility with different types of resins.1 For example, some studies1,4 mention that endodontically treated teeth, due to previously existing lesions and the procedures performed, often lose coronary tissue, requiring the placement of intraradicular posts that allow restoration of the nucleus or coronary stump, ultimately enabling final coronal restoration. However, several factors could influence the clinical performance of endodontically treated teeth restored with a combination of intra-root posts and crowns.5,8
Cementation is a critical procedure for adequate clinical performance of fiberglass posts, as it is important to achieve an adhesion force capable of withstanding masticatory forces in order to ensure adequate functionality and longevity of the posts/restorations.5 Therefore, it is necessary to investigate the adhesive strength of different protocols involving the use of adhesive cementation and fiberglass posts in root canals.
During the last few decades, many studies have focused on a variety of materials that can be used to prepare intraradicular posts and restore the coronary nucleus6,7 with different properties and fixing mechanisms, e.g., gold, stainless steel, titanium, or zirconium alloys, which are usually rigid, and fiberglass, which are flexible. Some studies8 analyzed the influence of adhesion on the transmission of forces from the post to the root dentin using finite element analysis; they found that the central placement of the post did not contribute to the transmission of loads, as opposed to the contribution of adhesion when intact. Ubaldini et al.5 reported that the adhesive failure of fiberglass poles accounted for 37% of all failure cases.
Thus, the aim of this study was to compare the bond strength of fiberglass posts using different adhesive cementation protocols.
MATERIALS AND METHODS
Sample Size
The sample was calculated by the mean comparison formula using Stata 15 software, with an Alpha of 0.05 and a beta of 0.8. A sample size (n = 30) of specimens was obtained for each group. The entire manuscript was written according to CRIS guidelines (Checklist for Reporting in vitro Studies).
Preparation of Specimens
Thirty single-rooted bovine teeth without structural defects and of similar dimensions were selected. Bovine teeth were used because they share similar characteristics to human incisors. Dental pieces were collected from animals slaughtered for reasons unrelated to the present study. They were disinfected by immersion in 0.1% thymol solution for 24 hours and then stored in distilled water and refrigerated. The crowns were cut at the level of the cement-adamantine junction with low-speed, water-cooled rotary instruments with a 22 mm diameter and 0.15 mm thick diamond bioactive disc (KG Sorensen, Sao Paulo, Brazil), obtaining roots that were 16 mm in length (Fig. 1A).
Endodontic Treatment
To facilitate endodontic treatment and subsequent placement of the fiberglass post, monoradicular teeth were used. Endodontic treatment was performed using rotary files (Protaper Universal System; Dentsply Maillefer, Ballaigues, Switzerland); 2.5% sodium hypochlorite solution was used for irrigation; gutta-percha tips (Dentsply Maillefer, Ballaigues, Switzerland) were used with the side condensation technique and an epoxy-based sealer (AH Plus; Dentsply Maillefer, Ballaigues, Switzerland) for sealing. After storage in distilled water at a temperature of 37°C for a day, the spaces for the posts in the root canals were prepared with the rotary instruments provided by the manufacturer of the posts (Whitepost DC No. 1; FGM, Sao Paulo, Brazil), with a length of 12 mm, in order to maintain 4 mm of apical sealing material, irrigating with sodium hypochlorite in 2.5% solution and then with distilled water (Fig. 1B).
Cementation Protocols
The posts were cleaned with 70% alcohol using a gauze for 15 seconds and air-dried; then, two layers of silane were actively placed for 1 minute each (Prosil; FGM, Brazil), allowing the solvent to evaporate. For the first group, an etch-and-rinse protocol with 37% orthophosphoric acid (Universal Scotchbond Etcher; 3M ESPE AG Dental Products Seefeld, Germany) was used, followed by the application of a universal adhesive (Single Bond Universal; 3M ESPE AG Dental Products Seefeld); for the second group, a self-etching protocol was used with the same universal adhesive and a dual-curing resin cement (RelyX Ultimate; 3M ESPE AG Dental Products Seefeld, Germany); for the third group, a protocol with self-adhesive cement was used (RelyX U200; 3M ESPE AG Dental Products Seefeld, Germany). The root canals of the teeth of the first group underwent acid etching for 15 seconds, followed by profuse washing with water for 60 seconds. The root canals of the first and second groups were dried with paper cones, and two layers of universal adhesive (single universal bond) were applied, followed by active rubbing; any excess was eliminated using paper cones and the solvent was allowed to evaporate for 15 seconds. Next, to the posts that were already cleaned and silane-embedded, in the first and second groups, a layer of adhesive was applied, and the solvent was allowed to evaporate using an air bulb for 15 seconds; next, the posts were cemented with dual polymerization resin cement (RelyX Ultimate). In the third group, only the canals were dried with paper cones, and the posts were cemented with self-adhesive cement (Relyx U200). The polymerization of the cement was carried out using a third-generation LED lamp (Valo, Ultradent, United States of America) for 40 seconds each on the buccal side and lingual side (Fig. 1C).
Assessment of Adhesion Strength
After cementation, the teeth were stored in distilled water at a temperature of 37°C for 24 hours. The samples were sectioned perpendicular to the long axis of the post, following ISO standards, using a 0.15 mm thick, 22 mm diameter diamond disc (KG Sorensen; Sao Paulo, Brazil) with low-speed rotary instruments, cooled with water. Specimens with a thickness of 2 mm were obtained for each third to be evaluated (cervical, middle, and apical). Thickness was measured using a digital caliper (Mitutoyo Corp, Kanogawa, Japan). Finally, the push-out test was performed using an Amsler universal testing machine (Amsler Equipment Inc., Ontario, Canada) (Fig. 1D).
Statistical Analysis
The collected data were analyzed using Stata® 15. Descriptive statistics and univariate analysis were performed to determine the mean, standard deviation, and maximum and minimum values. Normality was evaluated using the Shapiro–Wilk test. To determine the presence of a statistically significant difference among the group means, ANOVA was performed with a significance level of 0.05. In cases where significant differences were found, Bonferroni correction was performed for multiple pairwise comparisons.
RESULTS
The following in vitro results were obtained: the first group showed a mean adhesion strength of 21.2 ± 4.7 MPa; the second group of 22.6 ± 5.1 MPa; and the third group, of 12.3 ± 2.1 MPa (Table 1). At the cervical level, the average adhesion forces were 17.5 ± 5.2 MPa. At the level of the middle third, the average bond strength was 17.7 ± 5.4 MPa, while at the apical third level, it was 21.0 ± 7.3 MPa (Table 1).
Groups | Adhesión strength | SD | Min | Max | p* | p** | |
---|---|---|---|---|---|---|---|
Protocol | 1 | 21.2 | 4.7 | 14.4 | 34.5 | >0.05 | 0.001 |
2 | 22.6 | 5.1 | 15.5 | 34.5 | |||
3 | 12.3 | 2.1 | 8.9 | 16.6 | |||
Root third | Cervical | 17.5 | 5.2 | 10.3 | 29.8 | >0.05 | 0.05 |
Middle | 17.7 | 5.4 | 8.9 | 28.8 | |||
Apical | 21.0 | 7.3 | 11.5 | 34.5 |
Group 1: Bovine teeth with posts with an etch and rinse protocol with universal adhesive and adhesive resin cement
Group 2: Bovine teeth with a self-etching protocol with universal adhesive and resin cement
Group 3: Bovine teeth with a self-adhesive cement protocol
*Shapiro –Wilk test
**ANOVA, significance level (p < 0.05)
The normal distribution of the data was contrasted using the Shapiro–Wilk test; the data were normally distributed according to the adhesive cementation protocol (p > 0.05) and according to the apical third level (p > 0.05). Analysis of variance revealed significant differences (p = 0.001) between the groups according to the adhesive cementation protocol used, while no differences were found according to the root third level (p = 0.05) (Table 1). Therefore, using the Bonferroni post-hoc test, we found significant differences between Group 3 versus Group 1 and Group 3 versus Group 2 (p = 0.001) (Table 2).
Groups | Group 1 | Group 2 |
---|---|---|
Group 2 | 0.596 | – |
Group 3 | 0.001 | 0.001 |
Cervical | Middle | |
Middle | 1.000 | – |
Apical | 0.082 | 0.104 |
Group 1: Bovine teeth with posts with an etch and rinse protocol with universal adhesive and adhesive resin cement
Group 2: Bovine teeth with a self-etching protocol with universal adhesive and resin cement
Group 3: Bovine teeth with a self-adhesive cement protocol
Therefore, when performing the Bonferroni post-hoc test, it was found that there were only significant differences between Group 3 versus Group 1 and Group 3 versus Group 2 with p = 0.001 respectively (Table 2).
DISCUSSION
We evaluated the retention and resistance forces of the post systems’ adhesion to the root canal, such as conventional tensile or shear, microtension, and pull-out/push-out forces. In this study, we used the pushout test, where the load was applied along the longitudinal interface of the joint between the surfaces and the cement; it was a practical test that allowed the testing of many specimens.2
In this study, the bond strength was evaluated using different adhesive cementation protocols for bovine teeth. Limeira et al.9 found that the bond strength values, when using different adhesive cementation protocols, were not significantly different between young human teeth and young bovine teeth, which is why bovine teeth were used in this study. Furthermore, the adhesion strength values obtained with self-etching universal adhesive resin cement (Single Bond Universal and RelyX Ultimate) were not significantly different from those obtained with self-adhesive resin cement (RelyX U200). Similarly, Liu et al.10 found no significant differences between self-adhesive cement (RelyX Unicem) and etch-and-wash cement (Panavia F2.0); similarly, in the study by Pereira et al. (2014), no significant differences were found between etch-and-rinse resin cement (RelyX ARC, Panavia F, and Allcem) and self-adhesive resin cement (RelyX Unicem and BisCem), but modified glass ionomer resin cement (RelyX Luting 2) showed significantly lower values than both. In a similar vein, Lorenzetti et al.11 found similar values when using self-adhesive resin cement (Relyx U200) and luting glass ionomer cement (GC Gold Label 1), taking into account the mechanical limitations of ionomers compared to conventional luting resins.
Similar to the results of the aforementioned studies, no significant differences were found between the groups using universal adhesive resin cements with the etch-and-rinse protocol and self-etching protocol; in contrast to previous studies, significant differences were found between the other groups and the self-adhesive cement group (RelyX U200), which obtained significantly low values. Ubaldini et al.5 found that the groups in which cementation was carried out using a universal adhesive and resin cement (Scotchbond Universal and Relyx Ultimate) with the etch-and-wash protocol generated significantly higher adhesion strength forces than the group that used self-adhesive cement (RelyX U200). Similarly, Amiri et al.12 found significant differences in the values obtained with fourth-generation etch-and-rinse systems in conjunction with conventional resin cement (All Bond 2 and Duo-Link) when compared to those obtained with self-adhesive cement. In contrast, in the study by Graiff et al.13 significantly higher values were recorded with the use of self-adhesive cement (RelyX Unicem) than with the use of an etch-and-rinse system (Scotchbond Multi-Purpose Plus and RelyX ARC), although in this study, cementation was performed in Plexiglass simulators to evaluate the bond strength of the posts without taking root dentin into account.
On the other hand, in the study by Farid et al.14 there were no significant differences between the groups using universal self-etching adhesive with resin cement (Panavia F 2.0) and self-adhesive resin cement (Panavia SA cement Plus); however, when the ducts were overprepared, the film thickness of the ducts increased; the bond strength values of the group that used resin cement and self-etching adhesive were significantly higher than those of the group that used self-adhesive cement. In the study by Rodrigues et al.15 the canals were overprepared, and the posts were anatomized with composite resin for comparison of the adhesive strengths of the three cementation protocols; however, no significant differences were found between the etch-and-rinse (Adper Scotchbond Multi-Purpose and RelyX ARC), self-etch with universal adhesive (Scotchbond Universal Y RelyX Ultimate), and self-adhesive cement (RelyX Unicem 2) protocols.
When analyzing the adhesion strength in the root thirds of each group, no significant differences were found between the self-etching protocol with universal adhesive and self-adhesive cement protocol, but with the etch-and-rinse with universal adhesive protocol, the values of the apical third were significantly higher than the values of the cervical third, in contrast with the studies of Limeira et al. 9 in which the values at the apical third decreased significantly, of Rodrigues et al. 15 in which the values at the apical level were significantly lower than those at the cervical level, and of Amiri et al. 12 in which the values were significantly lower at the apical level than at the cervical level, with the same protocol.
One of the limitations was that the research carried out was experimental in vitro, so the results should be interpreted with caution because of the difficulty in extrapolating them accurately to a living organism. Another important factor when evaluating a luting agent is its binding capacity to the dentin substrate. Different studies have shown weak adhesion at this level, so it is important to evaluate the various cementation systems that present different treatments of the dentin surface, with protocols that can be sensitive to difficulties in handling the multiple materials that can be used, in addition to humidity control. It is necessary to consider the increasingly widespread use of universal adhesives, in its etching and rinsing modality, and in its self-etching modality, in addition to self-adhesive cements that allow simplifying the procedure, reducing the number of steps in the procedure.
The present research is a purely in vitro study, the considerations are different from in vivo studies, so the results should be taken with caution, however, its results are useful as a reference in making decisions regarding the protocol to be used for the restoration of endodontically treated teeth, due to the lack of well-designed clinical studies that provide strong evidence for such decision making.
Finally, this research is important because it sheds light on the properties and performance of various dental biomaterials, and in vitro studies were carried out in a controlled environment, future clinical studies can be planned to increase the level of evidence for developing clinical guidelines on the rehabilitation of teeth undergoing endodontic treatment. In addition, given the limited number16–19 of well-designed randomized clinical studies on the subject, i.e., the efficacy of fiberglass post cementation protocols, through in vitro studies, with tests that have demonstrated reliability, they provide useful information for clinical practice that can facilitate an adequate selection of materials and procedures, when it is required to rehabilitate teeth with endodontic treatment that requires the use of posts.
Therefore, it is important to carry out research with larger samples and a greater variety of adhesive luting materials than those used in the current study in order to compare the products available in the market that can be used in different protocols. In addition, studies should consider performing mechanical tests and examine the failure mode using a scanning electron microscope to analyze the fracture patterns at the interface level.
CONCLUSION
In summary, there were no significant differences between group 1 (bovine teeth treated with an etch-and-rinse protocol with universal adhesive and adhesive resin cement) and group 2 (bovine teeth treated with a self-etching protocol with universal adhesive and resin cement) with respect to adhesion force.
ACKNOWLEDGMENTS
Authors would like to thank the Faculty of Dentistry of the Universidad Nacional Federico Villarreal.
DATA AVAILABILITY STATEMENT
All data that support the study results are available from the corresponding author (Dr. Frank Mayta, e-mail: fmaytat@cientifica.edu.pe) on request.
ETHICAL ASPECTS
Because the study was an in vitro experimental study that worked with bovine teeth collected from animals that were slaughtered for human consumption, it was exempted from potential ethical conflicts.
REFERENCES
1. Figueiredo FE, Martins-Filho PR, Faria-E-Silva AL. Do metal post-retained restorations result in more root fractures than fiber post-retained restorations? A systematic review and meta-analysis. J Endod 2015;41(03):309–316. DOI: 10.1016/j.joen.2014.10.006
2. Robles G, Huertas-Mogollón G, Mendoza-Martiarena Y, et al. Comparison of the resistance of bond strength of cemented fiberglass posts in different root thirds with and without silanization: an ex vivo study. J Contemp Dent Pract 2020;21(03):261–266. DOI: 10.5005/jp-journals-10024–2774
3. Archana CH, Krishna Raju SM, Yadhav SS, et al. Effect of surface pretreatment and thermal activation of silane coupling agent on bond strength of fiber posts to resin cement. J Contemp Dent Pract 2019;20(11):1293–1296. DOI: 10.5005/jp-journals-10024–2687
4. Eid R, Azzam K, Skienhe H, et al. Influence of adaptation and adhesion on the retention of computer-aided design/computer-aided manufacturing glass fiber posts to root canal. J Contemp Dent Pract 2019;20(09):1003–1008. DOI: 10.5005/jp-journals-10024–2654
5. Ubaldini ALM, Benetti AR, Sato F, et al. Challenges in luting fibre posts: adhesion to the post and to the dentine. Dent Mater 2018;34(07):1054–1062. DOI: 10.1016/j.dental.2018.04.001
6. Sarkis-Onofre R, Fergusson D, Cenci MS, et al. Performance of post-retained single crowns: a systematic review of related risk factors. J Endod 2017;43(02):175–183. DOI: 10.1016/j.joen.2016.10.025
7. Naumann M, Sterzenbach G, Dietrich T, et al. Dentin-like versus rigid endodontic post: 11-year randomized controlled pilot trial on no-wall to 2-wall defects. J Endod 2017;43(11):1770–1775. DOI: 10.1016/j.joen.2017.06.030
8. Schmitter M, Rammelsberg P, Lenz J, et al. Teeth restored using fiber-reinforced posts: in vitro fracture tests and finite element analysis. Acta Biomater 2010;6(09):3747–3754. DOI: 10.1016/j.actbio.2010.03.012
9. Limeira FIR, Carvalho MFF, Nascimento VVD, et al. Bond strength of resin cements fixing fiber posts to human and bovine teeth of different ages. J Adhes Dent 2019;21(05):423–431. DOI: 10.3290/j.jad.a43180
10. Liu C, Liu H, Qian YT, et al. The influence of four dual-cure resin cements and surface treatment selection to bond strength of fiber post. Int J Oral Sci 2014;6(01):56–60. DOI: 10.1038/ijos.2013.83
11. Lorenzetti CC, Bortolatto JF, Ramos ATPR, et al. The effectiveness of glass ionomer cement as a fiber post cementation system in endodontically treated teeth. Microsc Res Tech 2019;82(07):1191–1197. DOI: 10.1002/jemt.23268
12. Amiri EM, Balouch F, Atri F. Effect of self-adhesive and separate etch adhesive dual cure resin cements on the bond strength of fiber post to dentin at different parts of theroot. J Dent (Tehran) 2017;14(03):153–158. PMC5694848.
13. Graiff L, Rasera L, Calabrese M, et al. Bonding effectiveness of two adhesive luting cements to glass fiber posts: pull-out evaluation of three different post surface conditioning methods. Int J Dent 2014:148571. DOI: 10.1155/2014/148571
14. Farid F, Rostami K, Habibzadeh S, et al. Effect of cement type and thickness on push-out bond strength of fiber posts. J Dent Res Dent Clin Dent Prospects 2018;12(04):277–282. DOI: 10.15171/joddd.2018.043
15. Rodrigues RV, Sampaio CS, Pacheco RR, et al. Influence of adhesive cementation systems on the bond strength of relined fiber posts to root dentin. J Prosthet Dent 2017;118(04):493–499. DOI: 10.1016/j.prosdent.2017.01.006
16. Almulhim KS, Oliveira-Haas L, Farhangpour A. Effect of resin cement, aging process, and root level on the bond strength of fiber-posts: an in vitro study. Am J Dent 2016;29(05):255–260. PMID: 29178737.
17. Zamanian AH, Hakimaneh SMR, Mojahedi SM, et al. Efficiency of erbium-doped yttrium aluminum garnet laser in debonding cemented glass fiber posts: an in vitro study. J Dent (Shiraz) 2021;22(01):1–7. DOI: 10.30476/DENTJODS.2020.83933.1062
18. Kırmalı Ö, Üstün Ö, Kapdan A, et al. Evaluation of various pretreatments to fiber post on the push-out bond strength of root canal dentin. J Endod 2017;43(07):1180–1185. DOI: 10.1016/j.joen.2017.03.006
19. Šimundić Munitić M, Bago I, Glockner K, et al. Effect of different laser treatments on the bond strength of intracanal fiber posts cemented with a self-adhesive resin cement. J Prosthodont 2019;28(01):e290-e296. DOI: 10.1111/jopr.12738
________________________
© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.